Shrink wrapping machines [Wrapping machines]
|
Application samples
In case of the conveyer, it is usually installed following operation method:
- RUN and STOP by remote control.
- Speed adjustment by an analog input(0-10V)
- Speed adjustment by the preset frequency
- Frequency free unit display
ex. F702 = [50m/min] / 60Hz = 0.83
Connection of inveters
Connection diagram of inverters (VF-nC3)
Setting table for inverters (VF-nC3)
Title |
Function |
Setting range |
Recommended setting |
|
Command mode selection |
0: Remote, 1: Local |
0 |
|
Frequency setting mode selection |
0: Remote, 1: Setting dial 1, 2: Setting dial 2, etc. |
0 |
|
Preset speed frequency 1 |
Lower limit frequency [LL] ~ Upper limit frequency [UL] |
20 |
|
Preset speed frequency 2 |
Lower limit frequency [LL] ~ Upper limit frequency [UL] |
40 |
|
Preset speed frequency 4 |
Lower limit frequency [LL] ~ Upper limit frequency [UL] |
60 |
|
Input terminal selection (R) |
0 to 201 |
14 |
|
Unit selection |
0: Disabled, 1: % => V/A |
2 |
|
Frequency units selection |
0.01 ~ 200 |
0.83 |
|