TOSHIBA Top PageJump to Main Text
 Contact us
 Site map
TOPPAGE
Product informationSupportTopicsApplicationMemberJapanese
  1. Top page
  2. Product information
  3. TOSVERT VF-nC1 

Product information

Typeform Input
phase
[PH]
Volatge
class
[V]
Capacity
[kW]
MCCB MC Wire size Screw size
Without
DCL
With
DCL
Without
DCL
With
DCL
Main
[mm2]
DCL
[mm2]
PBR
[mm2]
G/E
[mm2]
Main Control G/E
Rated
current
[A]
Typeform Rated
current
[A]
Typeform Typeform Typeform
VFNC1S-1001P11000.15NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-1002P11000.210NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-1004P11000.415NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-1007P11000.7530NJ30E--CA20-3.5--3.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1S-2002P12000.25NJ30E5NJ30ECA13CA132.01.25-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2002PL12000.25NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2004P12000.410NJ30E5NJ30ECA13CA132.01.25-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2004PL12000.410NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2007P12000.7515NJ30E10NJ30ECA13CA132.02.0-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2007PL12000.7515NJ30E--CA13-2.0--3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1S-2015P12001.520NJ30E15NJ30ECA20CA133.52.0-3.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1S-2015PL12001.520NJ30E--CA20-3.5--3.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1S-2022P12002.230NJ30E30NJ30ECA25CA205.52.0-5.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1S-2022PL12002.230NJ30E--CA25-5.5--5.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1-2001P32000.15NJ30E5NJ30ECA13CA132.01.25-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1-2002P32000.25NJ30E5NJ30ECA13CA132.01.25-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1-2004P32000.45NJ30E5NJ30ECA13CA132.01.25-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1-2007P32000.7510NJ30E5NJ30ECA13CA132.02.0-3.5M3M2(FL: M3)M3(FIN:M4)
VFNC1-2015P32001.515NJ30E10NJ30ECA13CA132.02.0-3.5M3.5M2(FL: M3)M3.5(FIN:M4)
VFNC1-2022P32002.220NJ30E15NJ30ECA13CA132.02.0-3.5M3.5M2(FL: M3)M3.5(FIN:M4)

NOTICE:
*1: [x2],[x3],[x4] means parallel number of cable.
*2: The wire size is for 600V HIV wire (75 degreeC).
    Ambient termperature is less than 50 degreeC and Wire length is less than 30m.
*3: The wire for control signal is shielded wire with 0.75mm2 or more.
*4: Please use large size wire for G/E compared than above table.

Page Top