Input voltage/Capacity range
3 phase 240V-0.4~55kW(HD)
3 phase 240V-0.75~75kW(ND)
3 phase 480V-0.4~280kW(HD)
3 phase 480V-0.75~315kW(ND)
IoT/Industry 4.0 Ready High Performance Drive TOSVERT TOSVERT VF-AS3

Standard specificaitons

Applicable motor
(kW)
HD*1 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 280
ND 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 280 315
Type
Form
3-phase 200V Class 2004P 2007P 2015P 2022P 2037P 2055P 2075P 2110P 2150P 2185P 2220P 2300P 2370P 2450P 2550P - - - - - - - -
3-phase 400V Class 4004
PC
4007
PC
4015
PC
4022
PC
4037
PC
4055
PC
4075
PC
4110
PC
4150
PC
4185
PC
4220
PC
4300
PC
4370
PC
4450
PC
4550
PC
4750
PC
4900
PC
4110
KPC
4132
KPC
4160
KPC
4200
KPC
4220
KPC
4280
KPC
Rating Output
capacity
(kVA)*2
200V Class HD 1.3 1.8 3.0 4.3 7.1 9.7 12.5 17.8 24.2 29.9 35.3 46.9 56.8 67.1 80.4 - - - - - - - -
200V Class ND 1.8 3.0 4.3 7.1 9.7 12.5 17.8 24.2 29.9 35.3 46.9 56.8 67.1 80.4 107 - - - - - - - -
400V Class HD 1.1 1.7 3.0 4.3 7.1 9.7 12.6 17.9 24.2 29.9 35.3 46.9 56.8 67.1 80.8 111 132 161 191 239 295 325 419
400V Class ND 1.7 3.0 4.3 7.1 9.7 12.6 17.9 24.2 29.9 35.3 46.9 56.8 67.1 80.8 111 132 161 191 230 325 367 419 469
Output
current
(A)*3
200V Class HD 3.3 4.6 8.0 11.2 18.7 25.4 32.7 46.8 63.4 78.4 92.6 123 149 176 211 - - - - - - - -
200V Class ND 4.6 8.0 11.2 18.7 25.4 32.7 46.8 63.4 78.4 92.6 123 149 176 211 282 - - - - - - - -
400V Class HD 1.5 2.2 4.0 5.6 9.3 12.7 16.5 23.5 31.7 39.2 46.3 61.5 74.5 88.0 106 145 173 211 250 314 387 427 550
400V Class ND 2.2 4.0 5.6 9.3 12.7 16.5 23.5 31.7 39.2 46.3 61.5 74.5 88.0 106 145 173 211 250 302 427 481 550 616
Power
supply
Voltage/
frequency
200V Class 3-phase 200 to 240V-50/60Hz (Voltage +10%, -15%, frequency ±5%)
400V Class 3-phase 380 to 480V-50/60Hz (Voltage +10%, -15%, frequency ±5%) 3-phase 380 to 440V-50Hz, 3-phase 380 to
480V-60Hz (Voltage +10%, -15%, frequency ±5%)
Output voltage 200V Class 3-phase 200V to 240V (The maximum output voltage is equal to the input supply voltage)
400V Class 3-phase 380V to 480V (The maximum output voltage is equal to the input supply voltage)
Overload current
rating
HD 150%-1minute, 180%-2seconds
ND 120%-1minute, 135%-2seconds
Output frequency range Setting between 0.01 to 590Hz, Default max. frequency is set to 0.01 to 80Hz, Maximum frequency adjustment(30 to 590Hz)
Protective method (IEC60529) IP20:200V class:0.4 to 37kW(HD), 400V class:0.4 to 75kW(HD), IP00:200V class:45 to 55kW(HD), 400V class:90 to 280kW(HD)
EMC filter Built-in:400V class
DC reactor Built-in:200V class, 400V class 0.4 to 132kW(HD), Attached:400V class 160 to 280kW(HD)
UL Type1 kit Built-in:200V class 0.4 to 37kW(HD), 400V class 0.4 to 75kW(HD), Optional:200V class 45 to 55kW(HD), 400V class 90 to 280kW(HD)
Ambient temperature*4 -10 to +60°C (Remove the upper cover if 50°C or more, max60°C)

*1 Parameter sets the driver for Normal Duty or Heavy Duty performance (Default).
*2 Capacity is calculated at 220V for the 200V class, at 440V for the 400V class.
*3 Rated output current when the PWM carrier frequency (parameter F300) is 4kHz for frame size 1 to 5, 2.5kHz for frame size 6 to 8.