Toshiba Toshiba Schneider Inverter Corporation

Fan,pump TOSVERT VF-PS1

Input voltage/Capacity range
3 phase 200V-0.4~90kW
3 phase 400V-0.75~630kW
3 phase 500V-1.5~500kW
3 phase 575V-2.0~700HP
3 phase 690V-2.2~630kW
3 phase 400V-0.75~90kW
(IP54)
ファン・ポンプ用 TOSVERT VF-PS1

Standard specificaitons

200V class

Item Specification
Applicable motor (kW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45
Rating Type VFPS1-
Form 2004PL 2007PL 2015PL 2022PL 2037PL 2055PL 2075PL 2110PM 2150PM 2185PM 2220PM 2300PM 2370PM 2450PM
Output Capacity (kVA) Note 1) 1.1 1.8 3.0 4.2 6.7 10.0 13 21 25 29 34 46 55 67
Output Current (A) Note 2) 3.0
(3.0)
4.8
(4.5)
8.0
(8.0)
11
(10.5)
17.5
(16.6)
27.5
(25.0)
33
(33)
54
(49)
66
(64)
75
(66)
88
(75)
120
(88)
144
(120)
176
(140)
Output Voltage 3-phase, 200 to 240 V (The maximum output voltage is the same as the input voltage.)
Overload current rating 120% - 1 minute 135% - 2 seconds
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor External options
Power supply Voltage-frequency 3-phase, 200 to 240 V . 50/60 Hz
Allowable fluctuation Voltage +10% - 15% Note 3) Frequency +/-5%
Protective method IP20 enclosed type (JEM1030) IP00 enclosed type (JEM1030) Note 4)
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 55 56 58 60 60 60 60 64 64 64
Color RAL7016
Built-in Filter EMC noise filter Note 5) Basic noise filter Note 6)
DC Reactor External option Built-in

400V class

Item Specification
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Rating Type VFPS1-
Form 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL
Output Capacity (kVA) Note 1) 1.8 3.1 4.4 8.0 11 13 21 25 31 37 50 60 72 88 122
Output Current (A) Note 2) 2.3
(2.3)
4.1
(4.0)
5.8
(5.3)
10.5
(8.6)
14.3
(13)
17.6
(17)
27.7
(25)
33
(32)
41
(37)
48
(38)
66
(53)
79
(60)
94
(75)
116
(93)
160
(120)
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload current rating 120% - 1 minute 135% - 2 seconds
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor External options
Power supply Voltage-frequency 3-phase, 380 to 480 V . 50/60 Hz
Allowable fluctuation Voltage +10% - 15% Note 3) Frequency +/-5%
Protective method IP20 enclosed type (JEM1030) IP00 enclosed type (JEM1030) Note 4)
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 56 56 58 60 60 60 64 64 64 64 64
Color RAL7016
Built-in Filter EMC noise filter Note 5)
DC Reactor External option Built-in

Note 1) Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 2) Rated output current when the PWM carrier frequency (parameter ) is 4kHz or less. The values in parentheses refer to rated output currents when set to 12kHz.
Note 3) +/-10% when the inverter is used continuously (load of 100%)
Note 4) Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.
Note 5) Complies with the Europian EMC Directive IEC/EN61800-3, 1st environment, category C2 or IEC/EN61800-3, 2nd environment, category C3
Note 6) Not complies with the European EMC Directive Core and capacities with external filter (optional) : Complies with the Europien EMC Directive.



Standard specifications (200 V class -55 to 75 kW)

Item Specification
Applicable motor (kW) 55 75 90
Rating Type VFPS1-
Form 2550P 2750P 2900P
Output Capacity (kVA) Note 1) 84 109 137
Output Current (A) Note 2) 221 285 359
Output Voltage 3-phase, 200 to 240 V (The maximum output voltage is the same as the input voltage.)
Overload Current Rating 120% - 1 minute 135% - 2 seconds
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor External options
Power supply Voltage/frequency 3-phase, 200 to 240 V . 50/60 Hz
Allowable Fluctuation Voltage +10% . 15% Note 3) Frequency +/-5%
Protective method IP00 open type (JEM1030) Note 4)
Cooling method Forced air cooling
Cooling fan noise (dBA) 61 61 70
Color RAL7016
Built-in Filter External filter (optional)
DC Reactor Attached DC reactor Note 5)

Standard specifications (400 V class -90 to 630 kW model)

Item Specification
Applicable motor (kW) 90 110 132 160 220 250 280 315 400 500 630
Rating Type VFPS1-
Form 4900PC 4110KPC 4132KPC 4160KPC 4220KPC 4250KPC 4280KPC 4315KPC 4400KPC 4500KPC 4630KPC
Output Capacity (kVA) Note 1) 136 164 197 239 325 367 419 469 578 717 905
Output Current (A) Note 2) 179 215 259 314 427 481 550 616 759 941 1188
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload Current Rating 120% - 1 minute, 135% - 2 seconds
Electric braking Dynamic Braking Circuit Built-in External options
Dynamic Breaking Resistor External options
Power supply Voltage/frequency Note 6) 3-phase, 380 to 440 V . 50 Hz
3-phase, 380 to 480 V . 60 Hz
Allowable Fluctuation Voltage +10% . 15% Note 3) Frequency +/-5%
Protective method IP00 open type (JEM1030) Note 4)
Cooling method Forced air cooling
Cooling fan noise (dBA) 61 61 72 73 73 76 76 76 76 76 78
Color RAL7016
Built-in Filter EMC noise filter Note 7)
DC Reactor Attached DC reactor Note 5)

Note 1) Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 2) Indicates the value when the PWM carrier frequency (parameter ) is 2.5 kHz or less. When low noise (PWM carrier frequency 8 kHz) is required at 18.5 kW or more, use an inverter of capacity one rank higher than the motor capacity.
Note 3) +/-10% when the inverter is used continuously (load of 100%)
Note 4) Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.
Note 5) For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor. However, this is unnecessary for DC input specifications.
Note 6) Three-phase 380~480V-50/60Hz
Note 7) Complies with the European EMC Directive
IEC/EN61800-3, 2nd environment, category C3



Totally enclosed box type

Item Specification
Voltage class 400V class
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Applicable motor (HP) 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125
Rating Type VFPS1-
Form PLE type 4007PLE 4015PLE 4022PLE 4037PLE 4055PLE 4075PLE 4110PLE 4150PLE 4185PLE 4220PLE 4300PLE 4370PLE 4450PLE 4550PLE 4750PLE 4900PLE
PDE type 4007PDE 4015PDE 4022PDE 4037PDE 4055PDE 4075PDE 4110PDE 4150PDE 4185PDE 4220PDE 4300PDE 4370PDE 4450PDE 4550PDE 4750PDE 4900PDE
Output capacity (kVA) [Note1] 1.8 3.1 3.9 6.9 9.1 12 17 23 28 33 45 54 65 78 104 124
Output current (A) [Note2] 2.3 4.1 5.1 9.1 12 16 22.5 30.5 37 43.5 58.5 71.5 85 103 137 163
Output voltage Three-phase 380~480V(The maximum output voltage is equal to the input supply voltage)
Overload current rating 110% - 1 minute
Electrical braking Dynamic braking circuit Built-in dynamic braking drive circuit
Dynamic braking resistor An external breaking resistor (optional)
Power supply Voltage-frequency Three-phase 380~480V-50/60Hz [Note3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency ±5%
Protective method Totally enclosed (JEM1030) IP54 / UL Type 12 [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 55 56 56 58 60 60 60 64 64 64 64 64
Color RAL7016
EMC filter PLE type IEC61800-3 category C2(EN55011 class A Group 1) filter Built-in IEC61800-3 category C3(EN55011 class A Group 2) filter Built-in
PDE type IEC61800-3 category C1(EN55011 class B Group 1) filter Built-in
DC reactor Built-in

Note 1: Capacity is calculated at 440V.
Note 2: Rated output current when the PWM carrier frequency (parameter CF) is 8kHz or less.
Note 3: An external power supply backup available (optional) (Type: CPS002Z)
Note 4: +/-10% when the inverter is used continuously (load of 100%).
Note 5: Drives with UL Type 12 conformity are optional. Contact your nearest Toshiba inverter distributor for them.