Toshiba Toshiba Schneider Inverter Corporation

High-performance Inverter TOSVERT VF-AS1

Input voltage/Capacity range
3 phase 200V-0.4~75kW
3 phase 400V-0.75~500kW
3 phase 500V-1.5~500kW
3 phase 575V-2.0~700HP
3 phase 690V-2.2~630kW
高機能インバータ TOSVERT VF-AS1

Standard specificaitons

200V class

Item Specification
Applicable motor (kW) 0.4 0.75 1.5 2.2 3.7/4.0 5.5 7.5 11 15 18.5 22 30 37 45
Rating Type VFAS1-
Form 2004PL 2007PL 2015PL 2022PL 2037PL 2055PL 2075PL 2110PM 2150PM 2185PM 2220PM 2300PM 2370PM 2450PM
Output Capacity (kVA) Note 1) 1.1 1.8 3.0 4.2 6.7 10.0 13 21 25 29 34 46 55 67
Output Current (A) Note 2) 3.0
(3.0)
4.8
(4.5)
8.0
(8.0)
11
(10.5)
17.5
(16.6)
27.5
(25.0)
33
(33)
54
(49)
66
(64)
75
(66)
88
(75)
120
(88)
144
(120)
176
(140)
Output Voltage 3-phase, 200 to 240 V (The maximum output voltage is the same as the input voltage.)
Overload current rating 150% - 1 minute
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor External options
Power supply Voltage-frequency 3-phase, 200 to 240 V . 50/60 Hz
Allowable fluctuation Voltage +10% - 15% Note 3) Frequency +/-5%
Protective method IP20 enclosed type (JEM1030) IP00 enclosed type (JEM1030) Note 4)
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 55 56 58 60 60 60 60 64 64 64
Color RAL7016
Built-in Filter EMI noise filter Note 5) Basic noise filter Note 6)
DC Reactor External option Built-in



400V class

Item Specification
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Rating Type VFAS1-
Form 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL
Output Capacity (kVA) Note 1) 1.8 3.1 4.4 8.0 11 13 21 25 31 37 50 60 72 88 122
Output Current (A) Note 2) 2.3
(2.3)
4.1
(4.0)
5.8
(4.6)
10.5
(8.6)
14.3
(13)
17.6
(17)
27.7
(25)
33
(32)
41
(37)
48
(38)
66
(53)
79
(60)
94
(75)
116
(93)
160
(120)
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload current rating 150% - 1 minute
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor Compatible with external options
Power supply Voltage-frequency 3-phase, 380 to 480 V . 50/60 Hz
Allowable fluctuation Voltage +10% - 15% Note 3) Frequency +/-5%
Protective method IP20 enclosed type (JEM1030) IP00 enclosed type (JEM1030) Note 4)
Cooling method Forced air-cooled
Cooling fan noise (dBA) 43 43 43 55 56 56 58 60 60 60 64 64 64 64 64
Color RAL7016
Built-in Filter EMI noise filter Note 5)
DC Reactor External option Built-in

Note 1) Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 2) Rated output current when the PWM carrier frequency (parameter ) is 4kHz or less. The values between parentheses refer to rated output currents when set to 12kHz.
Note 3) +/-10% when the inverter is used continuously (load of 100%)
Note 4) Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.
Note 5) Complies with the Europian EMC Directive IEC/EN61800-3, 1st environment, category C2 or IEC/EN61800-3, 2nd environment, category C3
Note 6) Not complies with the European EMC Directive Core and capacities with external filter (optional) : Complies with the Europien EMC Directive.



Standard specifications (200 V class -55 to 75 kW)

Item Specification
Applicable motor (kW) 55 75
Rating Type VFAS1-
Form 2550P 2750P
Output Capacity (kVA) Note 1) 84 109
Output Current (A) Note 2) 221 285
Output Voltage 3-phase, 200 to 240 V (The maximum output voltage is the same as the input voltage.)
Overload Current Rating 150%.1 minute
Electric braking Dynamic Braking Circuit Built-in
Dynamic Breaking Resistor Compatible with external options
Power supply Voltage/frequency 3-phase, 200 to 240 V . 50/60 Hz 3-phase, 200 to 220 V . 50 Hz
3-phase, 200 to 240 V . 60 Hz
Allowable Fluctuation Voltage +10% . 15% Note 3) Frequency +/-5%
Protective method IP00 open type (JEM1030) Note 4)
Cooling method Forced air cooling
Cooling fan noise (dBA) 61 72
Color RAL7016
Built-in Filter External filter (optional)
DC Reactor Attached DC reactor Note 5)



Standard specifications (400 V class -90 to 500 kW model)

Item Specification
Applicable motor (kW) 90 110 132 160 200 220 280 355 400 500
Rating Type VFAS1-
Form 4900PC 4110KPC 4132KPC 4160KPC 4200KPC 4220KPC 4280KPC 4355KPC 4400KPC 4500KPC
Output Capacity (kVA) Note 1) 136 164 197 239 295 325 419 511 578 717
Output Current (A) Note 2) 179 215 259 314 387 427 550 671 759 941
Output Voltage 3-phase, 380 to 480 V (The maximum output voltage is the same as the input voltage.)
Overload Current Rating 150% - 1 minute
Electric braking Dynamic Braking Circuit Built-in Compatible with external options
Dynamic Breaking Resistor Compatible with external options
Power supply Voltage/frequency Note 6) 3-phase, 380 to 440 V . 50 Hz
3-phase, 380 to 480 V . 60 Hz
Allowable Fluctuation Voltage +10% . 15% Note 3) Frequency +/-5%
Protective method IP00 open type (JEM1030) Note 4)
Cooling method Forced air cooling
Cooling fan noise (dBA) 61 72 73 73 76 76 76 76 76 78
Color RAL7016
Built-in Filter EMI noise filter Note 7)
DC Reactor Attached DC reactor Note 5)

Note 1) Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.
Note 2) Indicates the value when the PWM carrier frequency (parameter ) is 2.5 kHz or less. When low noise (PWM carrier frequency 8 kHz) is required at 18.5 kW or more, use an inverter of capacity one rank higher than the motor capacity.
Note 3) +/-10% when the inverter is used continuously (load of 100%)
Note 4) Inverters, 18.5kW or greater, do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.
Note 5) For 200V-55kW, 400V-90kW or larger model, be sure to install DC reactor. However, this is unnecessary for DC input specifications.
Note 6) Three-phase 380~480V-50/60Hz for 4900PC
Note 7) Complies with the European EMC Directive IEC/EN61800-3, 2nd environment, category C3



500V class

Item Specification
Voltage class 500V class
Applicable motor (kW) 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Rating Type VFAS1-
Form 5015PM 5022PM 5030PM 5040PM 5055PM 5075PM 6150PL 6185PL 6220PL 6300PL 6370PL 6450PL 6550PL 6750PL 6900PL
Output capacity (kVA) [Note 1] 2.8 3.9 5.1 6.5 8.7 12 17 21 26 31 41 52 59 74 90
Output current(A) [Note 2] 3.2 4.5 5.8 7.5 10 13.5 18.5 24 29 35 47 59 68 85 104
Output voltage Three-phase 500V~600V (The maximum output voltage is equal to the input supply voltage.) Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electric braking Dynamic braking circuit Built-in dynamic braking drive circuit
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~600V-50/60Hz [Note 3] Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP20 Enclosed type
Cooling method Forced air-cooled
Cooling fan noise (dBA) 60 64
Color RAL7016
EMC filter Basic filter (Not complies with the European EMC Directive) Built-in
Reactor External AC reactor (option) Built-in DC reactor

Item Specification
Voltage class 500V class
Applicable motor (kW) 90 110 132 160 200 250 315 400 500
Rating Type VFAS1-
Form 6110KPC 6132KPC 6160KPC 6200KPC 6250KPC 6315KPC 6400KPC 6500KPC 6630KPC
Output capacity (kVA) [Note 1] 118 143 173 208 270 295 400 511 641
Output current(A) [Note 2] 136 165 200 240 312 390 462 590 740
Output voltage Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electric braking Dynamic braking circuit Built-in dynamic braking drive circuit External dynamic braking circuit(option)
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP00 Open type [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA) 73 76 78
Color RAL7016
EMC filter Built-in
Reactor [Note 6] External AC reactor (option)

Note 1: Capacity is calculated at 500V for the 500V class.
Note 2: Rated output current when the PWM carrier frequency (parameter CF) is 2.5kHz.
Note 3: An external power supply backup available (option) (Type: CPS002Z)
Note 4: +/-10% when the inverter is used continuously (load of 100%).
Note 5: Inverters do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit.
Note 6: AC reactor (option): Mandatory for VFAS1-6110KPC and above.


575V class

Item Specification
Voltage class 575V class
Applicable motor (HP) 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100
Rating Type VFAS1-
Form 5015PM 5022PM 5040PM 5055P 5075PM 6150PL 6185PL 6220PL 6300PL 6370PL 6450PL 6550PL 6750PL 6900PL
Output capacity (kVA) [Note 1] 2.9 4.1 6.4 9.4 12 18 23 29 34 43 54 65 80 103
Output current(A) [Note 2] 2.7 3.9 6.1 9.0 11 17 22 27 32 41 52 62 77 99
Output voltage Three-phase 500V~600V
(The maximum output voltage is equal to the input supply voltage.)
Three-phase 500V~690V
(The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electrical braking Dynamic braking circuit Built-in dynamic braking drive circuit
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~600V-50/60Hz [Note 3] Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP20 Enclosed type
Cooling method Forced air-cooled
Cooling fan noise (dBA) 60 64
Color RAL7016
EMC filter Basic filter (Not complies with the European EMC Directive) Built-in
Reactor External AC reactor (option) Built-in DC reactor

Item Specification
Voltage class 575V class
Applicable motor (HP) 125 150 200 250 350 450 550 700
Rating Type VFAS1-
Form 6110KPC 6132KPC 6200KPC 6250KPC 6315KPC 6400KPC 6500KPC 6630KPC
Output capacity (kVA) [Note 1] 130 150 200 252 349 428 549 698
Output current(A) [Note 2] 125 144 192 242 336 412 528 672
Output voltage Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electrical braking Dynamic braking Built-in dynamic braking drive circuit External dynamic braking circuit(option)
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP00 Open type [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA) 73 76 78
Color RAL7016
EMC filter Built-in
Reactor [Note 6] External AC reactor (option)

Note 1: Capacity is calculated at 600V for the 575V class.
Note 2: Rated output current when the PWM carrier frequency (parameter CF) is 2.5kHz.
Note 3: An external power supply backup available (option) (Type: CPS002Z)
Note 4: +/-10% when the inverter is used continuously (load of 100%).
Note 5: Inverters do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit.
Note 6: AC reactor (option): Mandatory for VFAS1-6110KPC and above.



690V class

Item Specification
Voltage class 690V class
Applicable motor (kW) 2.2 3.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Rating Type VFAS1-
Form 6022PL 6030PL 6055PL 6075PL 6110PL 6150PL 6185PL 6220PL 6300PL 6370PL 6450PL 6550PL 6750PL 6900PL
Output capacity (kVA) [Note 1] 4.8 5.4 9.0 12 17 23 29 35 42 57 71 82 102 125
Output current(A) [Note 2] 4 4.5 7.5 10 13.5 18.5 24 29 35 47 59 68 85 104
Output voltage Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electrical braking Dynamic braking circuit Built-in dynamic braking drive circuit
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP20 Open type
Cooling method Forced air-cooled
Cooling fan noise (dBA) 64
Color RAL7016
EMC filter Built-in
Reactor Built-in

Item Specification
Voltage class 690V class
Applicable motor (kW) 110 132 160 200 250 315 400 500 630
Rating Type VFAS1-
Form 6110KPC 6132KPC 6160KPC 6200KPC 6250KPC 6315KPC 6400KPC 6500KPC 6630KPC
Output capacity (kVA) [Note 1] 150 180 215 263 347 424 502 649 806
Output current(A) [Note 2] 125 150 180 220 290 355 420 543 675
Output voltage Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Overload current rating 150%-1 minute, 165%-2 sec.
Electric braking Dynamic braking circuit Built-in dynamic braking drive circuit External dynamic braking circuit(option)
Dynamic braking resistor An external braking resistor (option)
Power supply Voltage-frequency Three-phase 500~690V-50/60Hz [Note 3]
Allowable fluctuation Voltage + 10% - 15% [Note 4] Frequency +/-5%
Protective method IP00 Open type [Note 5]
Cooling method Forced air-cooled
Cooling fan noise (dBA) 73 76 78
Color RAL7016
EMC filter Built-in
Reactor [Note 6] External AC reactor (option) or attached DC reactor

Note 1: Capacity is calculated at 690V for the 690V class.
Note 2: Rated output current when the PWM carrier frequency (parameter CF) is 2.5kHz.
Note 3: An external power supply backup available (option) (Type: CPS002Z)
Note 4: +/-10% when the inverter is used continuously (load of 100%).
Note 5: Inverters do not have wiring port covers. They have large openings, but there is no space to bend the external cables inside the unit.
Note 6: AC reactor (option): Mandatory for VFAS1-6110KPC and above.