Toshiba Toshiba Schneider Inverter Corporation

for HVAC TOSVERT VF-FS1

Capacity range
3ph 200V-0.4~30kW
3ph 400V-0.4~75kW
3ph 400V-0.75~75kW (IP54)
多機能・小型 TOSVERT VF-FS1

Standard specificaitons

200V class

Item Specification
Input voltage 3-phase 200V
Applicable motor (kW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
Rating Type VFFS1-
Form 2004PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM 2185PM 2220PM 2300PM
Capacity (kVA) Note 1) 1.1 1.8 2.9 4.0 6.7 9.2 12.2 17.6 23.2 28.5 33.5 44.6
Output current
(A) Note 2)
2.8 4.6 7.5 10.6 17.5 24.2 32 46.2 61 74.8 (67.3) 88.0 (79.2) 117.0 (105.3)
Output voltage Note 3) 3-phase 200V to 240V
Overload current rating 110%-60 seconds, 180%-2 second
Power
supply
Voltage-frequency 3-phase 200V to 240V -50/60Hz
Allowable fluctuation Voltage +10%, -15% Note 4), frequency +/-5%
Protective method IP20 Enclosed type (JEM1030) IP00 Enclosed type (JEM1030) Note 5)
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter Basic filter


400V class

Item Specification
Input voltage 3-phase 400V
Applicable motor (kW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
Rating Type VFFS1-
Form 4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL
Capacity (kVA) Note 1) 1.1 1.6 2.8 3.9 6.9 9.1 12.2 17.1 23.2 28.2 33.2 44.6
Rated output current
(A) Note 2)
1.4 2.2 3.7 5.1 9.1 12.0 16.0 22.5 30.5 37.0 (33.3) 43.5 (39.2) 58.5 (52.7)
Rated output voltage Note 3) 3-phase 380V to 480V
Overload current rating 110%-60 seconds, 180% -2 second
Power
supply
Voltage-frequency 3-phase 380V to 480V - 50/60Hz
Allowable fluctuation Voltage +10%, -15% Note 4), frequency +/-5%
Protective method IP20 Enclosed type (JEM1030) IP00 Enclosed type (JEM1030) Note 5)
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter EMC filter


Note 1: Capacity is calculated at 220V for the 200V models, at 440V for the 400V models.
Note 2: The rated output current in the parenthesis is at 12kHz of PWM carrier frequency (F300) setting.
Note 3: Maximum output voltage is the same as the input voltage.
Note 4: +/-10% when the inverter is used continuously (load of 100%).
Note 5: Inverter, 22kW or greater, do not have wiring port covers, they have large openings, but there is no space to bend the external cables inside the unit. If they are fitted external to the cabinet, please use an optional wiring port cover.



Totally-Enclosed Box Type

Item Specification
Voltage class 3-phase 400V class
Applicable motor (kW) 0.75 1.5 2.2 3.7 5.5 7.5
Model Voltage class Model number VFFS1
3-phase 400V class VFFS1- 4007PL1E
4007PDE
4015PL1E
4015PDE
4022PL1E
4037PDE
4037PL1E
4037PDE
4055PLE
4055PDE
4075PLE
4075PDE
Rating Capacity (kVA) Note 1: 1.6 2.8 3.9 6.9 9.1 12.2
Output current (A) Note 2: 3-phase 400V class 2.2 3.7 5.1 9.1 12.0 16.0
Output voltage Note 3: 3-phase 380 to 480V
Overload current rating 110%-1min., 180%-2 sec. (50%-reduction value)
Power supply Voltage-frequency 3-phase 380 to 480V-50/60Hz
Allowable fluctuation Voltage+10%, -15% Note 4:, frequency±5%
Protective method Totally enclosed type (JEM1030) compliant with IP54 Note 5:
Cooling method PL1E-type : Self-cooled PLE-type : Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter PLE, PL1E-type:EN61800-3, 1st Environment, C2 or 2nd Environment, C3
PDE-type:EN61800-3, 1st Environment, C1
Environments Use environments Indoor type. Altitude: Not more than 1000m.
Place free from corrosive and explosive gases
Ambient temperature -10 to +50 degreeC Note2
Storage temperature -25 to +70 degreeC
Relative humidity 20 to 93%
Vibration 5.9m/S2 or less (10 to 55Hz)

Item Specification
Voltage class 3-phase 400V class
Applicable motor (kW) 11 15 18.5 22 30 37
Model Voltage class Model number VFFS1
3-phase 400V class VFFS1- 4110PLE
4110PDE
4150PLE
4150PDE
4185PLE
4185PDE
4220PLE
4220PDE
4300PLE
4300PDE
4370PLE
4370PDE
Rating Capacity (kVA) Note 1: 17.1 23.2 28.2 33.2 44.6 52.0
Output current (A) Note 2: 3-phase 400V class 22.5 30.5 37.0
(33.3)
43.5
(39.2)
58.5
(52.7)
79.0
(71.1)
Output voltage Note 3: 3-phase 380 to 480V
Overload current rating 110%-1min., 180%-2 sec. (50%-reduction value)
Power supply Voltage-frequency 3-phase 380 to 480V-50/60Hz
Allowable fluctuation Voltage+10%, -15% Note 4:, frequency±5%
Protective method Totally enclosed type (JEM1030) compliant with IP54 Note 5:
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter PLE-type:EN61800-3, 2nd Environment, C3
PDE-type:EN61800-3, 1st Environment, C1
Environments Use environments Indoor type. Altitude: Not more than 1000m.
Place free from corrosive and explosive gases
Ambient temperature -10 to +50 degreeC Note2
Storage temperature -25 to +70 degreeC
Relative humidity 20 to 93%
Vibration 5.9m/S2 or less (10 to 55Hz)

Item Specification
Voltage class 3-phase 400V class
Applicable motor (kW) 45 55 75 - - -
Model Voltage class Model number VFFS1
3-phase 400V class VFFS1- 4450PLE
4450PDE
4550PLE
4550PDE
4750PLE
4750PDE
- - -
Rating Capacity (kVA) Note 1: 61.9 76.3 105.3 - - -
Output current (A) Note 2: 3-phase 400V class 94.0
(75.2)
116.0
(104.4)
160.0
(128.0)
- - -
Output voltage Note 3: 3-phase 380 to 480V
Overload current rating 110%-1min., 180%-2 sec. (50%-reduction value)
Power supply Voltage-frequency 3-phase 380 to 480V-50/60Hz
Allowable fluctuation Voltage+10%, -15% Note 4:, frequency±5%
Protective method Totally enclosed type (JEM1030) compliant with IP54 Note 5:
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter PLE-type:EN61800-3, 2nd Environment, C3
PDE-type:EN61800-3, 1st Environment, C1
Environments Use environments Indoor type. Altitude: Not more than 1000m.
Place free from corrosive and explosive gases
Ambient temperature -10 to +50 degreeC Note2
Storage temperature -25 to +70 degreeC
Relative humidity 20 to 93%
Vibration 5.9m/S2 or less (10 to 55Hz)

Note1) Capacity is calculated at 440V for the 400V models.
Note2) The values between parentheses refer to output currents at PWM carrier frequencies of over 12kHz. When installing the inverter where the ambient temperature will rise above 40degree, use the inverter with the rated output reduced. If the PWM carrier frequency is modified is necessary to reduce output current. Refer to following figures. If a motor cable over 30m in length is used, it is necessary to reduce them more. This means that the lives of the internal components will be shortened
Note3) The maximum output voltage is equal to the input supply voltage.
Note4) ±10% when the inverter is operated continuously (under a load of 100%).
Note5) IP54-compliant structures refer to structures that protect the contents from dust and harmful effects of water that drops from every direction. Use PG screw type cable grounds among cable grounds available are skin-top grounds manufactured by LAPP (Germany). When using this type of grounds, use them in combination with lock nuts.
Note6) For control specifications, parameters and functions, refer to the instruction manual E6581381.
Note7) The inverter has a built-in cooling fan. The cooling fan has a useful life of approximately 30,000 hours (2 to 3 years when operated continuously), so it needs to be replaced periodically. If the cooling fan does not operate normally, the temperatures of the internal electrical components will rise high, and as a result their lives will be shortened. So inspect it periodically.